your current location:首页 > news>GT5 installation cable automated fluid precision provision plan [GT5] Gregtech 5 (Gregtech 5) Minecraft Game

GT5 installation cable automated fluid precision provision plan [GT5] Gregtech 5 (Gregtech 5) Minecraft Game

2024-12-09 18:31:24|Myriagame |source:minecraft skins

This tutorial is set by the author to use the CC By-NC-ND protocol.

The version used in this tutorial Minecraft 1.7.10 version +GT5.09.32pre4 +OpenBlocks-1.7.10-1.6.jar +Appliednergistics2-RV3-BETA-6 +EXTRACLLS-1.7.10-2.3.14B200

One of the biggest difficulties in the production of automation production is how to accurately output the fluid according to the formula. However, due to the different cases required for different formula processing of different formulas, the amount of fluid consumed by a single processing is often not an integer multiple of 1,000. ThisAs a result, in the case of non -minimum batch processing, there is a fluid residue in the input warehouse of the assembly line, which is very inconvenient for continuous and multi -formula automation processing for the assembly line.

Let's start with two directions, how to solve this problem with a brief discussion

Option 1: After processing, use the catheter to clear the residual liquid

Active detection and detection cover version with equipment. With the improvement of the processing line processing progress, the redstone signal of the covered version has gradually increased, and a strong redstone signal connected to the liquid catheter connected to the output warehouse is drawn.Recover the AE network.

It is recommended to use the item catheter, last shadow liquid catheter, and insulating redstone catheter using the last shadow interface.The ducts of the last shadow interface can transmit items, liquids and redstone signals in a block. At the same time, it also has functions such as channels, filtration, and over -distance transmission. It can be reasonably simplified to greatly simplify the wiring and save space.

The following is a brief explanation:

It is currently processed a LUV electric motor. The fluid needs to consume melting welds*144MB, lubricating oil*250MB, according to the capacity of a fluid unit of 1000MB, 1000 as the unit, which provides a melting welding fluid unit*1. Lubricating oil unit*1 can meet the needs of processing once.

Note: Do not directly input the fluid unit into the input warehouse, otherwise the grid where the air unit returned cannot be drawn out

In order to return the empty unit smoothly, this example uses the last shadow interface lobe box with GUI, set the bottom to "push" to send the empty unit back to the ME interface to return to the network, and the input warehouse at the top of the fluid box is adjusted to input to input into inputThe electric pump covers the liquid in the fluid box.

The processing is close to the end, and the active detection of the equipment covered in the maintenance warehouse sends a strong redstone signal. The insulated redstone catheter sends the signal to the 4 last shadow liquid catheter connected to the 4 input warehouse.All the fluids in the input warehouse returned to the AE network through the AE fluid interface.

The example diagram of the device is shown below

It is not difficult to see that the solution can indeed solve the problem of fluid residues, but the defect is obvious. It can only be used in the form of processing only once.The fluid required for subsequent processing.

Option 2: Precisely control the fluid input, so that the formula processing is not left without fluid residue

It can be known that the formula consumed by the formula consumes a liquefied formula (such as fluid melting weld*144MB can be obtained by liquefaction through a welded ingot).The corresponding raw material of liquefaction can be left without fluid residues after processing, and there is no fluid (such as lubricating oil, UU, etc.) corresponding to the corresponding liquefied formula.Then, for these fluids, they need to be treated with other ways.

1. Update the Gray version to 5.09.32pre6, this version adds a fluid container that can freely set the maximum capacity (1 ~ 1000MB) -a measuring cylinder, or use a LuV electric motor as an example. Just set 144MB and 250MB separately respectivelyThe measuring cylinder of the two capacity can be filled with the fluid to the input warehouse; if the ZPM electric motor is required for 750MB, you only need to enter the 250MB measuring tube full of lubricating oil.Note: At present, there are bugs that cannot be produced by power warehouses in multi -square structures in the pre6 version. Please choose the upgraded version before. In addition, the various low -capacity clay liquid capsules of the clay industry can achieve this effect.use.

2. Use robots in the OC module for specified quantitative fluid transportation (accurate to 1MB). This module combined with AE can perfectly solve the problem of most Gray complex automation.However, because the entry of the module is more difficult, it is necessary to write complex procedures for LUA language. Interested players can learn, and no longer discuss it here.

3. Netizens suggest that the fluid flow regulator of IC2 can control the flow and time to achieve a specific quantitative fluid.

4. Use OpenBlocks's water storage tank; an important feature of the water storage tank is the default water storage tank to automatically allocate the liquid in the adjacent water storage tank. The following figure is the 4 -connected water storage tank loaded with 1000MB lubricant.The amount of lubricating oil is 250MB. If we can get a 250MB lubricant water storage tank in batches, it can be provided to the fluid box to provide accurate supply to all the assembly line formulas containing lubricating oil.It is a multiple of 250)

Here is a AE ME precise destruction panel and ME molding panel. Obtain 250MB of lubricant's water storage tank in batches through the formula formula of lubricating oil brewing room

It can be seen that the recipe can be seen that a brewing can get 750MB of lubricating oil, and the 750MB is divided into three average lubricating oil storage tanks with a average of 350MB.

Set the accurate matching of ME storage components on the component workbench so that the ME accurately destroys the panel can only destroy the 250MB lubricant water storage tank, and the molding panel is set to place the empty storage tank, and the water storage tank returned to the fluid box (insertThe best acceleration card is best) ME network is placed on the formation panel, so that you can repeat a large amount of 250MB lubricating oil storage sink by continuous circulation.When the lubricant water storage tank is set to set the value, turn off the production of lubricating oil and place the explosion box waste.

You can get different MB fluids by changing the number of water storage tanks (for example, enter 1000MB UU into 10 water storage tanks, you can get 10 100MB UU water storage tanks for processing neurons processor)